003719: Cannot write output to target folder. Target folder is read-only.

Description

The tool cannot write to the specified folder because the target folder is set to read-only.

If using the Apply Orbit Correction tool, this error can result when the tool attempts to update a metadata file that is in a read-only location.

Solution

Verify that you have write permissions to the target folder, or choose a different target folder.

When this error is caused by the Apply Orbit Correction tool, do one of the following:

  • Run the Remove Thermal Noise tool before running the Apply Orbit Correction tool. The output of the Remove Thermal Noise tool will be the input for the Apply Orbit Correction tool.
  • Alternatively, save the read-only data to a local folder you have write permissions for, and proceed with the standard workflow.