In a utility network, network rules dictate which features can connect to or associate with other types of features. The network rule base for a utility network is accessed from the network properties of a utility network.
Access utility network rules
- If the utility network layer is not present in a map, add it from the Catalog pane.
- In the Contents pane, right-click the utility network layer and click Properties to access the layer properties.
- On the Layer Properties dialog box, click the Network Properties tab.
For easier viewing, double-click the menu title to expand the dialog box.
- Scroll down on the dialog box to the Rules section. Expand this section to view information associated with each type of rule.
Tip:
The properties of the utility network can also be viewed from the Catalog pane by accessing the Utility Network Properties dialog box.
Details about each rule type
The following tables list the details for each rule type on the network properties page.
Junction-Junction Connectivity
Column | Description | Example |
---|---|---|
ID | The ID of the rule | 20 |
From Class | A utility network point feature class or junction object table | Electric Distribution Device |
From Asset Group | The asset group of the feature class | Valve |
From Asset Type | The asset type of the feature class | Double L Port |
From Terminal | The terminal of the asset type participating in the rule | Port 2 |
To Class | A utility network point feature class or junction object table | Electric Distribution Junction |
To Asset Group | The asset group of the feature class | Connection Point |
To Asset Type | The asset type of the feature class | Fitting |
To Terminal | The terminal of the asset type participating in the rule | None |
Created Time | The date and time the rule was created | 2017-01-17 10:05:30 |
Junction-Edge Connectivity
Column | Description | Example |
---|---|---|
ID | The ID of the rule | 16 |
From Class | A utility network point feature class or junction object table | Electric Distribution Device |
From Asset Group | The asset group of the feature class | Transformer |
From Asset Type | The asset type of the asset group | Mounted |
From Terminal | The terminal of the asset type participating in the rule | High |
To Class | A utility network line feature class or edge object table | Electric Distribution Line |
To Asset Group | The asset group of the feature class | Medium Voltage |
To Asset Type | The asset type of the asset group | Overhead |
Created Time | The date and time the rule was created | 2017-01-17 10:05:30 |
Edge-Junction-Edge Connectivity
Column | Description | Example |
---|---|---|
ID | The ID of the rule | 37 |
From Class | A utility network line feature class or edge object table | Electric Distribution Line |
From Asset Group | The asset group of the feature class | Medium Voltage |
From Asset Type | The asset type of the asset group | Overhead |
To Class | A utility network line feature class or edge object table | Electric Distribution Line |
To Asset Group | The asset group of the feature class | Low Voltage |
To Asset Type | The asset type of the asset group | Overhead |
Via Class | A utility network point feature class or junction object table | Electric Distribution Device |
Via Asset Group | The asset group of the feature class | Transformer |
Via Asset Type | The asset type of the asset group | Mounted |
Via Terminal | The terminal of the asset type participating in the rule | High |
Created Time | The date and time the rule was created | 2017-01-17 10:05:30 |
Containment
Column | Description | Example |
---|---|---|
ID | The ID of the rule | 259 |
Container Class | The container feature class or table | Structure Boundary |
Container Asset Group | The asset group of the container | Substation |
Container Asset Type | The asset type of the container | Border |
Content Class | The content feature class or table | Electric Distribution Device |
Content Asset Group | The asset group of the content | Breaker |
Content Asset Type | The asset type of the content | Circuit |
Created Time | The date and time the rule was created | 2017-01-17 10:05:30 |
Structural Attachment
Column | Description | Example |
---|---|---|
ID | The ID of the rule | 86 |
From Class | The structure feature class or table | Structure Junction |
From Asset Group | The asset group of the feature class | Pole |
From Asset Type | The asset type of the feature class | Wooden |
To Class | The attachment feature class or table | Electric Distribution Assembly |
To Asset Group | The asset group of the feature class | Transformer Bank |
To Asset Type | The asset type of the feature class | 3 Phase |
Created Time | The date and time the rule was created | 2017-01-17 10:05:30 |