Add Reduce Junction By Attribute Rule (Network Diagram)

Summary

Adds a diagram rule to automatically reduce diagram junctions during diagram building based on an existing template. The junctions to reduce are queried from a given network junction source class or object table by attributes according to the number of other junctions to which they are connected.

Learn more about the reduction of junctions in diagrams

Caution:

This tool is a configuration and administration tool.

Note:

This tool impacts the consistency of any existing diagrams based on the input diagram template. All of the existing diagrams become inconsistent and open with a consistency warning icon Diagram to update until they are updated.

Usage

  • This tool is not supported when working with a utility network or trace network service. You must use either a utility network or trace network in a file or mobile geodatabase, or a database connection to a utility network or trace network in an enterprise geodatabase. When working with an enterprise geodatabase, the following are requirements:

  • The Reduce Junction rule is used to simplify the diagram graph while preserving the topology.

    This tool allows the configuration of the Reduce Junction rule to run by attributes. It allows the configuration of the reduction of junctions in a given network junction class or object table by filtering the junctions to reduce by their attributes according to the number of junctions they are connected to and, optionally, to particular attributes on their adjacent edges.

Parameters

LabelExplanationData Type
Input Network

The utility network or trace network containing the diagram template that will be modified.

Utility Network; Trace Network
Input Diagram Template

The name of the diagram template that will be modified.

String
Active

Specifies whether the rule will be active when generating and updating diagrams based on the specified template.

  • Checked—The added rule will become active during the generation and update of any diagrams based on the input template. This is the default.
  • Unchecked—The added rule will not become active during the generation or update of any diagrams based on the input template.

Boolean
Junction Source to Reduce

The network junction source class or object table to process. All diagram junctions related to network junctions that belong to this source class or object table are reduction candidates.

Table; Feature Class
Expression
(Optional)

An SQL expression used to select the subset of network junctions from the junction reduction candidates in the diagrams based on the input template. For more information on SQL syntax, see the SQL reference for query expressions used in ArcGIS help topic.

SQL Expression
Reduce Junctions With
(Optional)

Specifies the number of junction connections that will be considered for reduction.

  • Maximum two connected junctionsJunctions with two or less connections will be considered. In this case, a specific process will be run according to the number of candidate junction connections that will be reduced. This is the default.
  • Minimum three connected junctionsJunctions with three or more connections will be considered. In this case, upstream traces will be run to determine whether candidate junction connections will be reduced.
String
Reduce if unconnected
(Optional)

Specifies whether each unconnected network diagram junction candidate will be reduced. This parameter is only active when Reduce Junctions With is set to Maximum two connected junctions.

  • Checked—Unconnected network diagram junction candidates will be reduced. Each junction will be removed.
  • Unchecked—Unconnected network diagram junction candidates will not be reduced; they will be kept. This is the default.

Boolean
Reduce if connected to a single junction
(Optional)

Specifies whether each network diagram junction reduction candidate that is connected to a single junction will be reduced. This parameter is only active when Reduce Junctions With is set to Maximum two connected junctions.

  • Checked—Network diagram junction reduction candidates that are connected to a single junction will be reduced. Each junction and its incident edge will be reduced onto its single connected junction.
  • Unchecked—Network diagram junction reduction candidates that are connected to a single junction will not be reduced; they will be kept. This is the default.

Boolean
Reduce if connected to 2 different junctions
(Optional)

Specifies whether each network diagram junction reduction candidate that is connected to two other junctions will be reduced. This parameter is only active when Reduce Junctions With is set to Maximum two connected junctions.

  • Checked—Network diagram junction reduction candidates that connect two other junctions will be reduced. Each junction and its incident edges will be reduced onto a super span edge (the reduction edge). This is the default.
  • Unchecked—Network diagram junction reduction candidates that connect two other junctions will not be reduced; they will be kept.

Boolean
Edge Attribute Names
(Optional)

The alias of the edge attributes adjacent to the junction reduction candidate.

The junction will be reduced only when all of its adjacent edges have the same values for each specified attribute alias.

String
Description
(Optional)

The description of the rule.

String

Derived Output

LabelExplanationData Type
Output Network

The updated utility network or trace network.

Utility Network; Trace Network
Output Diagram Template

The name of the diagram template.

String

arcpy.nd.AddReduceJunctionByAttributeRule(in_utility_network, template_name, is_active, junction_source, {where_clause}, {connectivity_options}, {unconnected_junctions}, {one_connected_junction}, {two_connected_junctions}, {edges_attributes}, {description})
NameExplanationData Type
in_utility_network

The utility network or trace network containing the diagram template that will be modified.

Utility Network; Trace Network
template_name

The name of the diagram template that will be modified.

String
is_active

Specifies whether the rule will be enabled when generating and updating diagrams based on the specified template.

  • ACTIVEThe added rule will become enabled during the generation and update of any diagrams based on the input template. This is the default.
  • INACTIVEThe added rule will not become enabled during the generation or update of any diagrams based on the input template.
Boolean
junction_source

The network junction source class or object table to process. All diagram junctions related to network junctions that belong to this source class or object table are reduction candidates.

Table; Feature Class
where_clause
(Optional)

An SQL expression used to select the subset of network junctions from the junction reduction candidates in the diagrams based on the input template. For more information on SQL syntax, see the SQL reference for query expressions used in ArcGIS help topic.

SQL Expression
connectivity_options
(Optional)

Specifies the number of junction connections that will be considered for reduction.

  • MAX_2_CONNECTED_JUNCTIONSJunctions with two or less connections will be considered. In this case, a specific process will be run according to the number of candidate junction connections that will be reduced. This is the default.
  • MIN_3_CONNECTED_JUNCTIONSJunctions with three or more connections will be considered. In this case, upstream traces will be run to determine whether candidate junction connections will be reduced.
String
unconnected_junctions
(Optional)

Specifies whether each unconnected network diagram junction candidate will be reduced. This parameter is only enabled when connectivity_options = "MAX_2_CONNECTED_JUNCTIONS".

  • REDUCE_UNCONNECTED_JCTUnconnected network diagram junction candidates will be reduced. Each junction will be removed.
  • KEEP_UNCONNECTED_JCTUnconnected network diagram junction candidates will not be reduced; they will be kept. This is the default.
Boolean
one_connected_junction
(Optional)

Specifies whether each network diagram junction reduction candidate that is connected to a single junction will be reduced. This parameter is only enabled when connectivity_options = "MAX_2_CONNECTED_JUNCTIONS".

  • REDUCE_JCT_TO_1JCTNetwork diagram junction reduction candidates that are connected to a single junction will be reduced. Each junction and its incident edge will be reduced onto its single connected junction.
  • KEEP_JCT_TO_1JCTNetwork diagram junction reduction candidates that are connected to a single junction will not be reduced; they will be kept. This is the default.
Boolean
two_connected_junctions
(Optional)

Specifies whether each network diagram junction reduction candidate that is connected to two other junctions will be reduced. This parameter is only enabled when connectivity_options = "MAX_2_CONNECTED_JUNCTIONS".

  • REDUCE_JCT_TO_2JCTSNetwork diagram junction reduction candidates that connect two other junctions will be reduced. Each junction and its incident edges will be reduced onto a super span edge (the reduction edge). This is the default.
  • KEEP_JCT_TO_2JCTSNetwork diagram junction reduction candidates that connect two other junctions will not be reduced; they will be kept.
Boolean
edges_attributes
[edges_attributes,...]
(Optional)

The alias of the edge attributes adjacent to the junction reduction candidate.

The junction will be reduced only when all of its adjacent edges have the same values for each specified attribute alias.

String
description
(Optional)

The description of the rule.

String

Derived Output

NameExplanationData Type
out_utility_network

The updated utility network or trace network.

Utility Network; Trace Network
out_template_name

The name of the diagram template.

String

Code sample

AddReduceJunctionByAttributeRule example (stand-alone script)

This sample script adds a Reduce Junction By Attribute rule to the MyTemplate1 template existing for a given network to systematically reduce any electric nonprotective distribution devices—that is, any device that is not a network protector or a switch—that are unconnected or connected to two other junctions in the generated diagrams.

import arcpy
input_Network = "D:/MyProjectLocation/MyDatabaseConnection.sde/MyDatabase.MAP.Electric/MyDatabase.MAP.Electric"
input_DiagramTemplate = "MyTemplate1"
input_JunctionClassToReduce = "D:/MyProjectLocation/MyDatabaseConnection.sde/MyDatabase.MAP.Electric/MyDatabase.MAP.ElectricDistributionDevice"

arcpy.AddReduceJunctionByAttributeRule_un(input_Network, input_DiagramTemplate, 
                                          "ACTIVE", input_JunctionClassToReduce, 
                                          "ASSETTYPE <> 11 And ASSETTYPE <> 8", 
                                          "MAX_2_CONNECTED_JUNCTIONS", 
                                          "REDUCE_UNCONNECTED_JCT",
                                          "KEEP_JCT_TO_1JCT","REDUCE_JCT_TO_2JCTS")
AddReduceJunctionByAttributeRule example 2 (stand-alone script)

This sample script adds a Reduce Junction By Attribute rule to the MyTemplate2 template existing for a given network to systematically reduce any electric nonprotective distribution devices when they connect two other junctions and their adjacent edges have the same values for the Asset type and Phases attributes.

import arcpy
input_Network = "D:/MyProjectLocation/MyDatabaseConnection.sde/MyDatabase.MAP.Electric/MyDatabase.MAP.Electric"
input_DiagramTemplate = "MyTemplate2"
input_JunctionClassToReduce = "D:/MyProjectLocation/MyDatabaseConnection.sde/MyDatabase.MAP.Electric/MyDatabase.MAP.ElectricDistributionDevice"
input_Alias1 = "Asset type"
input_Alias2 = "Phases"

arcpy.AddReduceJunctionByAttributeRule_nd(input_Network, input_DiagramTemplate, 
                                          "ACTIVE", input_JunctionClassToReduce, 
                                          "ASSETTYPE <> 11 And ASSETTYPE <> 8", 
                                          "MAX_2_CONNECTED_JUNCTIONS", 
                                          "KEEP_UNCONNECTED_JCT", "KEEP_JCT_TO_1JCT",
                                          "REDUCE_JCT_TO_2JCTS", 
                                          input_Alias1 + ";" + input_Alias2)

Environments

This tool does not use any geoprocessing environments.

Licensing information

  • Basic: No
  • Standard: Yes
  • Advanced: Yes

Related topics