040034: Specified Sill matrix is not positive definite in the semivariogram model.

Description

This error may occur in cokriging or indicator kriging. The system of equations cannot be solved if the matrix is not positive definite.

Solution

Try modifying the parameters of the model (semivariogram type, nugget, and sill). Small changes may resolve the problem.