Label | Explanation | Data Type |
Input Utility Network
| The utility network for which the rule will be added. | Utility Network; Utility Network Layer |
Rule Type
| Specifies the type of rule that will be created.
| String |
From Table
| The from utility network feature class or nonspatial object that will be included in the rule. Structural attachment and containment association rules require that the container or structure network feature be in this parameter. When creating junction-edge and edge-junction-edge connectivity rules, this parameter must reference the junction or junction object. | String |
From Asset Group
| An asset group for the From Table parameter value to which the rule will apply. | String |
From Asset Type
| An asset type for the From Table parameter value to which the rule will apply. | String |
To Table
| The to utility network feature class or nonspatial object that will be included in the rule. Structural attachment and containment associations rules require that the content or attachment network feature be in this parameter. When creating junction-edge and edge-junction-edge connectivity rules, the From Table parameter must reference the junction or junction object. | String |
To Asset Group
| An asset group for the To Table parameter value to which the rule will apply. | String |
To Asset Type
| An asset type for the To Table parameter value to which the rule will apply. | String |
From Terminal
(Optional) | The from terminal to which the rule will apply. This will be a terminal in the From Table parameter value. When creating a connectivity rule for a device or junction object with terminals to connect to another network feature, the terminal side to connect from must be specified, for example, the high-side terminal on a transformer. This parameter is required if the asset type has terminals. It is inactive when the structural attachment or containment association rule is specified in the Rule Type parameter. | String |
To Terminal (Optional) | The to terminal to which the rule will apply. This will be a terminal in the To Table parameter value. When creating a connectivity rule for a for a device or junction object to connect to another network feature with terminals, the terminal side to connect to must be specified, for example, the low-side terminal on a transformer. This parameter is required if the asset type has terminals. It is inactive for structural attachment or containment association rule types. | String |
Via Table
(Optional) | The junction utility network feature class or object to which the rule will apply. This parameter is available only when the Rule Type parameter is set to Edge-junction-edge connectivity, since three classes are required to participate in edge-junction-edge connectivity. | String |
Via Asset Group
(Optional) | An asset group of the Via Table parameter value to which the rule will apply. This parameter is available only when the Rule Type parameter is set to Edge-junction-edge connectivity. | String |
Via Asset Type
(Optional) | An asset type of the Via Table parameter value to which the rule will apply. This parameter is available only when the Rule Type parameter is set to Edge-junction-edge connectivity. | String |
Via Terminal
(Optional) | The terminal from the Via Table parameter value to which the rule will apply. This parameter is available only when the Rule Type parameter is set to Edge-junction-edge connectivity. | String |
Derived Output
Label | Explanation | Data Type |
Updated Utility Network | The updated utility network. | Utility Network |