003228: Invalid junction object was discovered.

Description

A junction object was found that is not valid to participate in the tier pursuant to the subnetwork definition. The subnetwork name with invalid features is provided in the error.

Errors are generated for the invalid junction objects when running the Update Subnetwork tool.

Solution

Review the reported errors for invalid features and inspect the asset group and asset type.

To manually identify the asset groups and asset types that are invalid, perform a subnetwork trace for the subnetwork specified. Use the selected objects in the junction object table to compare the asset group and asset type combinations with the valid junction objects for the tier.

Review the utility network properties for the valid junction objects for the tier: Click the domain network drop-down arrow and expand Tiers. Review the asset group and asset type combinations in the Valid Junction Objects column.

To resolve this error, do one of the following:

  • Change the asset group and asset type of the invalid object.
  • Change the subnetwork definition for the tier to include additional valid junction objects. See Set or modify the subnetwork definition for more information.