Event behavior for route calibration

适用于 Location Referencing 许可。

When route calibration occurs, events are impacted, depending on the event behavior configured for each event layer.

注:

Events are not updated until the Apply Event Behaviors geoprocessing tool is applied after route edits. If you are using conflict prevention, you are prompted to run Apply Event Behaviors, which must be done before posting can be completed.

The following sections detail the results of executing this tool on event features.

Calibration can occur on a route when one or more calibration points are added, edited, or deleted. These calibration point changes can be made using the calibration tools on the Location Referencing tab in ArcGIS Pro or by checking the Record calibration changes for event location updates option when running the Generate Routes geoprocessing tool.

Route calibration scenario

This route calibration scenario involves one route with two existing calibration points. A calibration point at existing measure 10 will be changed to 15, resulting in recalibrated measures downstream.

Before Calibration

Stay Put behavior

The geographic location of the event is maintained; the measures may change.

Stay Put event behavior

Move behavior

The measures of the event are maintained; the geographic location may change.

Move event behavior

Retire behavior

The geographic location and measures are maintained; the event retires.

Retire event behavior

Upstream and downstream sections

Route editing impacts upstream and downstream sections differently. Use the following diagrams and table to understand this impact for the configured event behavior.

The following diagram shows the upstream and downstream sections for the pending edit.

Upstream and Downstream

The following table details how the calibration editing activity impacts upstream and downstream events according to the configured event behavior.

Behavior Events upstream of calibration point edit Events crossing calibration point edit Events downstream of calibration point edit

Stay Put

Measures on an event update to maintain the geographic location, if the event crosses the section between the edited calibration point and the nearest upstream calibration point.

Measures on an event update to maintain the geographic location of the event.

Measures on an event update to maintain the geographic location of the event. If the event crosses the section between the edited calibration point and the nearest upstream calibration point, measures update due to calibration point values changing.

Move

The event polyline shape updates to the new location of measures on the route if the event crosses the section between the edited calibration point and the nearest upstream calibration point.

The event polyline shape is updated to the new location of measures on the route.

The event polyline shape is updated to the new location of measures on the route if crossing a section of the route with a calibration point with measures is updated.

Retire

The event retires if the event crosses the section between the edited calibration point and the nearest upstream calibration point.

The event retires; line events crossing the edited calibration point are not split.

The event retires if the event crosses a section of the route with a calibration point with measures updated.

注:
  • Point events follow the same behavior as linear events but don't need to be split.
  • If the option to recalibrate route downstream is chosen, the events downstream of the edited portion of the route will have calibrate route event behaviors applied.
  • The network may contain events that span multiple routes in a line network. In that case, the behaviors are still applied in the same manner.
  • Since the LRS is time aware, edit activities such as calibrating or retiring a route will time slice routes and events.
  • If the route is calibrated the same day that it's created, and the event behavior for calibrate is set to retire, the events will be deleted not retired.

Detailed behavior results

The following sections detail how event behavior rules are enforced when a route is calibrated.

Stay Put behavior

A calibration point is added to the route at existing measure 10 with an effective date of 1/1/2000. The added calibration point has a new measure of 15 with recalibrate downstream applied and an effective date of 1/1/2005. This calibration will have the following effects:

  • Event1 will be represented by two time slices because the route recalibrated to the nearest upstream calibration point with measure 5. There will be a time slice as of 1/1/2000 to 1/1/2005, with the original measures of 0 to 7, and a time slice as of 1/1/2005 to <null> that will stay in the same location geographically but have the new measures 0 to 9 of Route1.
  • Event2 will also be represented by two time slices because it crosses the location where the recalibration took place on the route. There will be a time slice as of 1/1/2000 to 1/1/2005, with the original measures of 7 to 15, and a time slice as of 1/1/2005 to <null> that will stay in the same location geographically but have the new measures 9 to 20 of Route1.
  • Event3 will be represented by two time slices because it crosses the location on the route where it was recalibrated downstream. There will be a time slice as of 1/1/2000 to 1/1/2005, with the original measures of 15 to 20, and a time slice as of 1/1/2005 to <null> that will stay in the same location geographically but have the new measures 20 to 25 of Route1.

Before Stay Put event behavior

The following diagram and table provide details about the route and its measures before calibration.

Before Stay Put event behavior
The route measure is 10; add a calibration point with measure 15 and recalibrate downstream.

EventRoute nameFrom dateTo dateFrom measureTo measure

Event1

Route1

1/1/2000

<null>

0

7

Event2

Route1

1/1/2000

<null>

7

15

Event3

Route1

1/1/2000

<null>

15

20

After Stay Put event behavior

The following diagram and table detail how event behavior rules are enforced after extension when Stay Put is the configured event behavior.

After Stay Put event behavior

EventRoute nameFrom dateTo dateFrom measureTo measure

Event1

Route1

1/1/2000

1/1/2005

0

7

Event1

Route1

1/1/2005

<null>

0

9

Event2

Route1

1/1/2000

1/1/2005

7

15

Event2

Route1

1/1/2005

<null>

9

20

Event3

Route1

1/1/2000

1/1/2005

15

20

Event3

Route1

1/1/2005

<null>

20

25

Move behavior

A calibration point is added to the route at existing measure 10, with an effective date of 1/1/2000. The added calibration point has a new measure of 15 with recalibrate downstream applied and an effective date of 1/1/2005. This calibration will have the following effects:

  • Event1 will be represented by two time slices because the route recalibrated to the nearest upstream calibration point with measure 5. There will be a time slice as of 1/1/2000 to 1/1/2005 with the original measures of 0 to 7. The second time slice will be as of 1/1/2005 to <null> with measures of 0 to 7 that will maintain the original event measures but have the geographic x,y location move to the new location of those measures on the route because the route recalibrated to the nearest upstream calibration point with measure 5.
  • Event2 will also be represented by two time slices because it crosses the location where the recalibration took place on the route. There will be a time slice as of 1/1/2000 to 1/1/2005 with the original measures of 7 to 15. The second time slice will be as of 1/1/2005 to <null> with measures of 7 to 15 that will maintain the original event measures but have their geographic x,y location move to the new location of those measures on the route.
  • Event3 will be represented by two time slices because it crosses the location on the route where it was recalibrated downstream. There will be a time slice as of 1/1/2000 to 1/1/2005 with the original measures of 15 to 20. The second time slice will be as of 1/1/2005 to <null> with measures of 15 to 20 that will maintain the original event measures but have their geographic x,y location move to the new location of those measures on the route.

Before Move event behavior

The following diagram and table provide details about the route and its measures before calibration.

Before Move event behavior

EventRoute nameFrom dateTo dateFrom measureTo measure

Event1

Route1

1/1/2000

<null>

0

7

Event2

Route1

1/1/2000

<null>

7

15

Event3

Route1

1/1/2000

<null>

15

20

After Move event behavior

The following diagram and table detail how event behavior rules are enforced after extension when Move is the configured event behavior.

After Move event behavior

EventRoute nameFrom dateTo dateFrom measureTo measure

Event1

Route1

1/1/2000

1/1/2005

0

7

Event1

Route1

1/1/2005

<null>

0

7

Event2

Route1

1/1/2000

1/1/2005

7

15

Event2

Route1

1/1/2005

<null>

7

15

Event3

Route1

1/1/2000

1/1/2005

15

20

Event3

Route1

1/1/2005

<null>

15

20

Retire behavior

A calibration point is added to the route at existing measure 10 with an effective date of 1/1/2000. The added calibration point has a new measure of 15 with recalibrate downstream applied and an effective date of 1/1/2005. This calibration will have the following effects:

  • Event1 will retire because the route recalibrated to the nearest upstream calibration point with measure 5.
  • Event2 will retire because it crosses the location where the recalibration took place on the route.
  • Event3 will retire because it crosses the location on the route where it was recalibrated downstream.

Before Retire event behavior

The following diagram and table provide details about the route and its measures before calibration.

Before Retire event behavior

EventRoute nameFrom dateTo dateFrom measureTo measure

Event1

Route1

1/1/2000

<null>

0

7

Event2

Route1

1/1/2000

<null>

7

15

Event3

Route1

1/1/2000

<null>

15

20

After Retire event behavior

The following diagram and table detail how event behavior rules are enforced after extension when Retire is the configured event behavior.

After Retire event behavior

EventRoute nameFrom dateTo dateFrom measureTo measure

Event1

Route1

1/1/2000

1/1/2005

0

7

Event2

Route1

1/1/2000

1/1/2005

7

15

Event3

Route1

1/1/2000

1/1/2005

15

20

Detailed behavior results on routes in a line network with events that span routes

The following sections detail how event behavior rules are enforced when a route on a line in a line network is calibrated.

Events are not updated until the Apply Event Behaviors geoprocessing tool is applied. If you are using conflict prevention, you will be prompted to run Apply Event Behaviors, which must be done before posting can be completed.

Stay Put behavior

A calibration point is added to the route at existing measure 28 with a new measure value of 31 and an effective date of 1/1/2005. Recalibrate downstream is not applied. This calibration will have the following effects:

  • Event1 will be represented by two time slices. There will be a time slice from 1/1/2000 to 1/1/2005, with the original measures of 0 on Route1 to 30 on Route3, and a time slice from 1/1/2005 to <null> that will stay in the same location geographically but have the new measures 0 on Route1 to 33 on Route3.
  • Event2 will also be represented by two time slices. There will be a time slice from 1/1/2000 to 1/1/2005, with the original measures of 30 on Route3 to 48 on Route4, and a time slice from 1/1/2005 to <null> that will stay in the same location geographically but have the new measures 33 on Route3 to 48 on Route4.

Before Stay Put event behavior

The following diagram and table provide details about the routes, events, and measures before calibration of the edit region.

注:

Calibration points affect only the route where they are added or updated.

Before Stay Put event behavior

Event IDFrom DateTo DateFrom RouteIDTo Route IDFrom MeasureTo Measure

Event1

1/1/2000

<null>

Route1

Route3

0

30

Event2

1/1/2000

<null>

Route3

Route4

30

48

After Stay Put event behavior

The following diagram and table detail how event behavior rules are enforced after extension when Stay Put is the configured event behavior.

After Stay Put event behavior

Event IDFrom DateTo DateFrom RouteIDTo Route IDFrom MeasureTo Measure

Event1

1/1/2000

1/1/2005

Route1

Route3

0

30

Event1

1/1/2005

<null>

Route1

Route3

0

33

Event2

1/1/2000

1/1/2005

Route3

Route4

30

48

Event2

1/1/2005

<null>

Route3

Route4

33

48

Move behavior

A calibration point is added to the route at existing measure 28 with an effective date of 1/1/2005. The added calibration point has a new measure of 31 without recalibration downstream applied. This calibration will have the following effects:

  • Event1 will be represented by two time slices. There will be a time slice from 1/1/2000 to 1/1/2005, with the original measures of 0 on Route1 to 30 on Route3, and a time slice from 1/1/2005 to <null>, also with measures 0 on Route1 to 30 on Route3. The measure 30 moves to the new geographic location of the measure on Route3.
  • Event2 will also be represented by two time slices. There will be a time slice from 1/1/2000 to 1/1/2005, with the original measures of 30 on Route3 to 48 on Route4, and a time slice from 1/1/2005 to <null>, also with measures of 30 on Route3 to 48 on Route4. The measure 30 moves to the new geographic location of the measure on Route3.

Before Move event behavior

The following diagram and table provide details about the routes, events, and measures before calibration of the edit region.

Before Move event behavior

Event IDFrom DateTo DateFrom RouteIDTo Route IDFrom MeasureTo Measure

Event1

1/1/2000

<null>

Route1

Route3

0

30

Event2

1/1/2000

<null>

Route3

Route4

30

48

After Move event behavior

The following diagram and table detail how event behavior rules are enforced after extension when Move is the configured event behavior.

After Move event behavior

Event IDFrom DateTo DateFrom RouteIDTo Route IDFrom MeasureTo Measure

Event1

1/1/2000

1/1/2005

Route1

Route3

0

30

Event1

1/1/2005

<null>

Route1

Route3

0

30

Event2

1/1/2000

1/1/2005

Route3

Route4

30

48

Event2

1/1/2005

<null>

Route3

Route4

30

48

Retire behavior

A calibration point is added to the route at existing measure 28 with a new measure value of 31 and an effective date of 1/1/2005. Recalibrate downstream is not applied. This calibration will have the following effects:

  • Event1 will retire because it intersects with the route that is recalibrated.
  • Event2 will retire because it intersects with the route that is recalibrated.

Before Retire event behavior

The following diagram and table provide details about the routes, events, and measures before calibration of the edit region.

Before Retire event behavior

Event IDFrom DateTo DateFrom RouteIDTo Route IDFrom MeasureTo Measure

Event1

1/1/2000

<null>

Route1

Route3

0

30

Event2

1/1/2000

<null>

Route3

Route4

30

48

After Retire event behavior

The following diagram and table detail how event behavior rules are enforced after extension when Retire is the configured event behavior.

Both events are impacted so both events are retired.

After Retire event behavior

EventFrom DateTo DateFrom RouteIDTo Route IDFrom MeasureTo Measure

Event1

1/1/2000

1/1/2005

Route1

Route3

0

30

Event2

1/1/2000

1/1/2005

Route3

Route4

30

48